If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Power Transformer 41FJ020 2.74 2.24 1.25 2.28 6.69 .390 2-.260 x .190 1 5 4 2 3 3.25 3.65 Dimensions: In. Specifications: * Primary voltage: 115VAC 60Hz * Primary exciting current: 100mA (max.) * Secondary voltage (no load): 20.6CT VAC0.8V% * Secondary voltage (full load): 18.0CT VAC0.8V% * Rated secondary current: 2.0 Amperes (AC) 60Hz * Voltage regulation: less than 15% (VNL-VFL)/(VFL)x100 * Temperature rise (@ room temp. 25C): less than 95C * Breakdown voltage (HiPOT): 2000VAC 50Hz, 1minute * Coil to coil insulation: 100M (min.) 500VDC * Strain relief: 10 lbs. * Channel frame material & thickness: iron 0.4" * Crossover insulation: .002" polyester tape * Primary winding: SWG28 * Secondary winding: SWG22+28 * Core size: EI-66 * Core material: hilite core H-23 .02" * Inner insulation: 3 layers of .002" polyester tape * Outer wrap insulation: 3 layers of 0.05mm polyester tape w/1 pc. of fiber board (yellow) * Bobbin: nylon, normal type .87" x 1.8" * Impregnation: varnish * Lead wire: Pri. AWG22, Sec. AWG18 or AWG22 XICON PASSIVE COMPONENTS * (800) 628-0544 XC-600072 Specifications are subject to change without notice. No liability or warranty implied by this information. Environmental compliance based on producer documentation. Date Revised: 11/2/05 |
Price & Availability of 41FJ020 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |